Ethernet Access Switch MES1124M

Overview
Specifications
Reviews
  • Advanced L2 functions
  • Stacking support
  • Multicast support (IGMP Snooping, MVR)
  • Advanced security functions (L2-L4 ACL, IP Source Guard, Dynamic ARP Inspection, etc.)
The switches provide end users connection to the networks of large enterprises, small and medium-sized businesses and service provider networks using Fast and Gigabit Ethernet interfaces .
The access switches support physical stacking, VLANs and multicast groups, as well as advanced security features.

Uninterruptible power supply
MES1124MB and MES2124MB switches have the ability to connect storage battery in order to provide uninterruptible power in case of 220V supply line failure.
The switches are equipped with the power supply unit that allows charging of storage battery if the 220V supply line is available. The power system provides monitoring of power supply line and notifies of power source switching.

Protection against voltage surges
MES switches are equipped with efficient protection technology against voltage surges (up to 6 kV) caused by lightning discharges. 
Interfaces functions
  • Head-of-line blocking (HOL) protection
  • Back Pressure
  • Auto MDI/MDIX
  • Jumbo frames
  • Flow Control (IEEE 802.3X)
  • Port mirroring
  • VLAN mirroring
MAC table functions
  • Independent learning mode per VLAN
  • MAC Multicast Support
  • Configurable aging time of MAC addresses per VLAN
  • Static MAC Entries
  • MAC change events monitoring per ports
  • MAC flapping events monitoring per ports
VLAN functions
  • Voice VLAN
  • IEEE 802.1Q
  • Q-in-Q
  • Selective Q-in-Q
  • GVRP
L2 Multicast functions
  • Multicast profiles
  • Static Multicast groups
  • IGMP Snooping v1,2,3
  • Port/host-based IGMP Snooping Fast Leave
  • IGMP authorization via RADIUS
  • MLD Snooping v1,2
  • IGMP Querier
  • MVR
L2 functions
  • STP (Spanning Tree Protocol, IEEE 802.1d)
  • RSTP (Rapid Spanning Tree Protocol, IEEE 802.1w)
  • MSTP (Multiple Spanning Tree Protocol, IEEE 802.1s)
  • STP Multiprocess
  • STP Root Guard
  • STP Loop Guard
  • STP BPDU Guard
  • BPDU Filtering
  • Spanning Tree Fast Link option
  • Layer 2 Protocol Tunneling
  • Private VLAN
  • ERPS (G.8032v2)
  • EAPS
  • Loopback Detection (LBD) per VLAN
  • Port Isolation
  • Flex Link (Dual homing)
  • Storm Control for different traffic types (broadcast, multicast, unknown unicast)
Link Aggregation functions
  • Static LAG
  • Dynamic LAG (LACP)
  • LAG Balancing Algorithms
IPv6 functions
  • IPv6 Host
  • Dual-stack
Service functions
  • Virtual Cable Testing (VCT)
  • Optical transceiver diagnostics
  • Green Ethernet
Security functions
  • DHCP Snooping
  • DHCP Option 82
  • IP Source Guard
  • Dynamic ARP Inspection
  • sFlow
  • MAC-based authentication, Port Security, Static MAC entries
  • Port-based authentication IEEE 802.1x
  • Guest VLAN
  • DoS attack prevention
  • Traffic segmentation
  • Protection against non-authorized DHCP servers
  • DHCP clients filtering
  • BPDU attack prevention
  • NetBIOS/NetBEUI filtering
  • PPPoE Intermediate agent
  • SSH server operation algorithm selection
ACL (Access Control Lists)
  • L2-L3-L4 ACL
  • Time-based ACL
  • IPv6 ACL
  • ACL-ONLY with increased switch resources
  • ACL based on:
    • – Physical port number
      – IEEE 802.1p
      – VLAN ID
      – Ethertype
      – DSCP
      – Protocol type
      – TCP/UDP port number
      – User Defined Bytes
Quality of Service (QoS) and rate limiting
  • Shaping, Policing
  • IEEE 802.1p Class of Service (CoS)
  • Storm Control
  • Bandwidth management
  • Scheduling algorithms: Strict Priority/Weighted Round Robin (WRR)
  • Three marking colors
  • ACL-based traffic classification
  • ACL-based CoS/DSCP assignment
  • DSCP to CoS remarking
  • CoS to DSCP remarking
  • ACL-based VLAN assignment
ОАМ
  • IEEE 802.3ah Ethernet OAM
  • Dying Gasp
  • IEEE 802.1ag Connectivity Fault Management (CFM)
  • IEEE 802.3ah Unidirectional Link Detection (UDLD)
Management functions
  • Download and upload of configuration file via TFTP/SCP
  • SNMP
  • Command Line Interface (CLI)
  • Web interface
  • Syslog
  • SNTP (Simple Network Time Protocol)
  • Traceroute
  • LLDP (IEEE 802.1ab) + LLDP MED
  • Configuration of user privilege level
  • Management interface blocking
  • Local authentication
  • IP addresses filtering for SNMP
  • RADIUS and TACACS+ (Terminal Access Controller Access Control System) clients
  • SSH server
  • SSL
  • Macrocommands
  • CLI commands logging via TACACS+
  • DHCP autoprovision
  • DHCP Relay (IPv4 support)
  • DHCP Option 12
  • DHCP Relay Option 82
  • PPPoE Circuit-ID tag
  • Flash File System
  • Debugging commands
  • Rate limit of traffic to CPU
  • Password encryption
  • Password recovery
  • Ping (IPv4/IPv6 support)
  • IPv4/IPv6 static routes for management network
  • 2 configuration files
Monitoring functions
  • Interface statistics
  • RMON/SMON
  • CPU utilization monitoring per task and per traffic type
  • RAM utilization monitoring
  • Temperature monitoring
  • TCAM utilization monitoring
MIB
  • RFC 1065, 1066, 1155, 1156, 2578 MIB Structure
  • RFC 1212 Concise MIB Definitions
  • RFC 1213 MIB II
  • RFC 1215 MIB Traps Convention
  • RFC 1493, 4188 Bridge MIB
  • RFC 1157, 2571-2576 SNMP MIB
  • RFC 1901-1908, 3418, 3636, 1442, 2578 SNMPv2 MIB
  • RFC 271,1757, 2819 RMON MIB
  • RFC 2465 IPv6 MIB
  • RFC 2466 ICMPv6 MIB
  • RFC 2737 Entity MIB
  • RFC 4293 IPv6 SNMP Mgmt Interface MIB
  • Private MIB
  • RFC 3289 DIFFSERV MIB
  • RFC 2021 RMONv2 MIB
  • RFC 1398, 1643, 1650, 2358, 2665, 3635 Ether-like MIB
  • RFC 2668 IEEE 802.3 MAU MIB
  • RFC 2674, 4363 IEEE 802.1p MIB
  • RFC 2233, 2863 IF MIB
  • RFC 2618 RADIUS Authentication Client MIB
  • RFC 4022 MIB for TCP
  • RFC 4113 MIB for UDP
  • RFC 3298 MIB for Diffserv
  • RFC 2620 RADIUS Accounting Client MIB
  • RFC 2925 Ping & Traceroute MIB
  • RFC 768 UDP
  • RFC 791 IP
  • RFC 792 ICMPv4
  • RFC 2463, 4443 ICMPv6
  • RFC 4884 Extended ICMP to support for Multi-Part messages
  • RFC 793 TCP
  • RFC 2474, 3260 DS field in the IPv4 and IPv6 header
  • RFC 1321, 2284, 2865, 3580, 3748 Extensible Authentication Protocol (EAP)
  • RFC 2571, RFC2572, RFC2573, RFC2574 SNMP
  • RFC 826 ARP
Technical features
  • Power supply: 220 VAC 50 Hz, 48 VDC
  • Operating temperature: from -15° to +50°С
  • Storage temperature: from -40° to +70°С
  • Operating humidity: 80% max
  • Passive cooling
  • Dimensions - 430х158х44 mm
  • Form factor: 19'', 1U